Control LCV 2xx
Control LCV 2xx series control cabinets are smart control and protection devices with extended functionality for 1 or 2 pumps.
Characteristics
Number of pumps
—
1 / 2
Ambient temperature range
—
-10°С ... +40°С
Rated power (P2) of one pump
—
up to 15 kW
Mains frequency
—
50 Hz
Rated voltage
—
1 × 220 V / 3 × 380 V
Maximum current consumption
—
до 32 А
Control LCV 2xx
Scopes of application:
– Water discharge from a well or pit
– Industrial sewage systems
– Filling a reservoir from a borehole or well
– Pumping liquid from one reservoir to another
– Water delivery from a borehole
– Increasing pressure in water supply systems
– Circulation in heating and cooling systems
Functions:
– LCD display and buttons on Russian
– Automatic and manual operation modes
– Float-based operation (up to 4 pcs. KR1 or up to 5 pcs. MS1), electrodes and pressure relays
– separate float for "dry run" – operation based on analog level or pressure sensor
– automatic sequencing of pumps
– pump switching in case of fault
– joint operation of 2 pumps
– Display of total time of pump operation
– Button lock
– Memory upon power shutdown and recovery
– Pump start and stop delay
– Digital inputs/outputs
– Remote emergency shutdown of pumps
– RS485, Modbus RTU communication bus
– Embedded buzzer and emergency beacon
Control and protection:
– "Dry run" without sensors
– Jamming and overload
– Increased and reduced pressure
– Loss, unbalance and incorrect sequencing of phases
– Frequent repeated starts
– Overheating of pumps with embedded sensors PTC/KLIXON or Pt100
– Leakage for pumps with leakage sensor
– Pump shaft protection against corrosion in case of long-term downtime
– Water discharge from a well or pit
– Industrial sewage systems
– Filling a reservoir from a borehole or well
– Pumping liquid from one reservoir to another
– Water delivery from a borehole
– Increasing pressure in water supply systems
– Circulation in heating and cooling systems
Functions:
– LCD display and buttons on Russian
– Automatic and manual operation modes
– Float-based operation (up to 4 pcs. KR1 or up to 5 pcs. MS1), electrodes and pressure relays
– separate float for "dry run" – operation based on analog level or pressure sensor
– automatic sequencing of pumps
– pump switching in case of fault
– joint operation of 2 pumps
– Display of total time of pump operation
– Button lock
– Memory upon power shutdown and recovery
– Pump start and stop delay
– Digital inputs/outputs
– Remote emergency shutdown of pumps
– RS485, Modbus RTU communication bus
– Embedded buzzer and emergency beacon
Control and protection:
– "Dry run" without sensors
– Jamming and overload
– Increased and reduced pressure
– Loss, unbalance and incorrect sequencing of phases
– Frequent repeated starts
– Overheating of pumps with embedded sensors PTC/KLIXON or Pt100
– Leakage for pumps with leakage sensor
– Pump shaft protection against corrosion in case of long-term downtime
Characteristics
|
Number of pumps
|
1 / 2 |
|
Ambient temperature range
|
-10°С ... +40°С |
|
Rated power (P2) of one pump
|
up to 15 kW |
|
Mains frequency
|
50 Hz |
|
Rated voltage
|
1 × 220 V / 3 × 380 V |
|
Maximum current consumption
|
до 32 А |
|
Protection class (IEC 34-5)
|
IP65 |
Documents