Hydro-FS
Complete pumping units Hydro-FS-A/V are designed for utilization in automatic sprinkler and drench systems of water and foam fire extinguishing, as well as in hydrant-equipped systems. Shipment period – min. 2 weeks.
Hydro-FS-A/V units can be used to protect the following facilities:
• residential buildings with various number of floors,
• shopping and entertainment centers,
• production and warehouse facilities,
• cultural and social facilities.
Details
Characteristics
Pump family
—
Hydro-FS
Max flow
—
13 - 170 m³/h
Maximum head
—
24 - 166 m
Number of pumps
—
2 / 3
Max working pressure
—
16 bar
Liquid temperature range
—
5 .. 60 °C
Hydro-FS
Hydro-FS-A fire extinguishing units are developed based on SP485 regulations and are designed primarily for utilization in automatic fire extinguishing systems.
These systems take water from open water bodies, firewater tanks or various water pipelines. Due to possible complicated suction conditions, these units are equipped with enlarged diameter pipelines, enabling maintenance of the required speed of liquid flow.
The units are initialized by two certified pressure relays; suction and delivery pipelines have built-in cut-off gates.
Hydro-FS-A fire extinguishing units are developed based on SP10 regulations and are designed primarily for utilization in internal fire-fighting water pipelines. These systems take water from a municipal network a guaranteed head, meaning that conditions on the suction side allow to use less pipeline diameters. Unit start is initiated by two pressure sensors. By default, this type of units does not have cutoff gates on collectors, but they can be pre-installed as an option.
These systems take water from open water bodies, firewater tanks or various water pipelines. Due to possible complicated suction conditions, these units are equipped with enlarged diameter pipelines, enabling maintenance of the required speed of liquid flow.
The units are initialized by two certified pressure relays; suction and delivery pipelines have built-in cut-off gates.
Hydro-FS-A fire extinguishing units are developed based on SP10 regulations and are designed primarily for utilization in internal fire-fighting water pipelines. These systems take water from a municipal network a guaranteed head, meaning that conditions on the suction side allow to use less pipeline diameters. Unit start is initiated by two pressure sensors. By default, this type of units does not have cutoff gates on collectors, but they can be pre-installed as an option.
Characteristics
|
Pump family
|
Hydro-FS |
|
Max flow
|
13 - 170 m³/h |
|
Maximum head
|
24 - 166 m |
|
Number of pumps
|
2 / 3 |
|
Max working pressure
|
16 bar |
|
Liquid temperature range
|
5 .. 60 °C |
|
Size of inlet connection
|
DN80 - DN200 |
|
Size of outlet connection
|
DN80 - DN200 |
|
Rated power (P2) of one pump
|
0,75 - 30 kW |
|
Mains frequency
|
50 Hz |
|
Rated voltage
|
3 x 380/415 V |
|
Protection class (IEC 34-5)
|
IP54 |