VNK
VNK pumps are single-stage cantilever centrifugal pumps. The pumps are equipped with asynchronous electric motors with air cooling. Pumping part, coupling and electric motors are mounted independently on a common frame, enabling maintenance of the pump appliances without dismantling. Every pumping appliance undergoes verification and adjustment of alignment on the manufacturing factory. Bearing node can be made in various versions, including for severe operation conditions. The pumps are embedded with a mechanical shaft end seal, and its flow part is assembled with special bronze gap seals, increasing service life of pump components.
Characteristics
Max flow
—
up to 1750 m³/h
Maximum head
—
up to 150 m
Max working pressure
—
16 / 25 bar
Liquid temperature range
—
-20 .. 150 °C
Max. ambient temp.
—
40 °C
Housing material
—
чугун НТ250 (QT500)
VNK
VNK pumps are single-stage cantilever centrifugal pumps. The pumps are equipped with asynchronous electric motors with air cooling. Pumping part, coupling and electric motors are mounted independently on a common frame, enabling maintenance of the pump appliances without dismantling. Every pumping appliance undergoes verification and adjustment of alignment on the manufacturing factory. Bearing node can be made in various versions, including for severe operation conditions. The pumps are embedded with a mechanical shaft end seal, and its flow part is assembled with special bronze gap seals, increasing service life of pump components.
These pumps can be used various areas, the most common of which are listed below:
∙ centralized heat supply systems (including heat generation systems)
∙ heating systems
∙ air conditioning systems
∙ centralized cooling supply systems
∙ water supply
∙ irrigation
∙ industrial processes
∙ industrial cooling
VNK pumps are suitable for pumping of non-viscous, explosion-proof and non-flammable liquids, not containing solid or fiber inclusions. If the pumped liquids have higher density and/or viscosity than water, it is recommended to use pumps with more powerful motors. Decision on whether a pump is suitable for pumping a particular liquid, depends on many factors, the most important of which is chloride contents, pH value, temperature and chemicals contents, etc. To assess compatibility with special liquids, contact Vandjord specialists.
These pumps can be used various areas, the most common of which are listed below:
∙ centralized heat supply systems (including heat generation systems)
∙ heating systems
∙ air conditioning systems
∙ centralized cooling supply systems
∙ water supply
∙ irrigation
∙ industrial processes
∙ industrial cooling
VNK pumps are suitable for pumping of non-viscous, explosion-proof and non-flammable liquids, not containing solid or fiber inclusions. If the pumped liquids have higher density and/or viscosity than water, it is recommended to use pumps with more powerful motors. Decision on whether a pump is suitable for pumping a particular liquid, depends on many factors, the most important of which is chloride contents, pH value, temperature and chemicals contents, etc. To assess compatibility with special liquids, contact Vandjord specialists.
Characteristics
|
Max flow
|
up to 1750 m³/h |
|
Maximum head
|
up to 150 m |
|
Max working pressure
|
16 / 25 bar |
|
Liquid temperature range
|
-20 .. 150 °C |
|
Max. ambient temp.
|
40 °C |
|
Housing material
|
чугун НТ250 (QT500) |
|
Size of inlet connection
|
DN 100 - DN 350 |
|
Size of outlet connection
|
DN 80 - DN 350 |
|
Impeller material
|
cast iron HT200; stainless steel 304 |
|
Motor standard
|
IEC |
|
Rated power – P2
|
3 - 355 kW |
|
Mains frequency
|
50 Hz |
|
Rated current
|
6,3 - 554 A |
|
Motor rotation speed
|
2900 / 1450 / 960 rpm |
|
Number of poles
|
2 / 4 / 6 |
|
Protection class (IEC 34-5)
|
IP55 |
|
Insulation class (IEC 85)
|
F |
|
Energy efficiency class
|
IE3 |
Documents
Photo gallery
1/3
—